福島第一原子力発電所 3 号機事故の熱流動現象の推定 ―高圧注水系(HPCI)が途中で止まった場合―


英字タイトル:
Heat and Fluid Flow in Accident of Fukushima Daiichi Nuclear Power Plant, Unit 3 - When the high pressure coolant injection system (HPCI) stopped -
著者:
円山 重直 Shigenao MARUYAMA
発刊日:
公開日:
カテゴリ: 論文
キーワードタグ:

概要

An accident scenario of Fukushima Daiichi Nuclear Power Plant, Unit 3 is analyzed from the data open to the public. The author assumed that the high pressure coolant injection system (HPCI) stopped before TEPCO stopped it manually, and the vapor in the reactor pressure vessel (RPV) is condensed in the condensate storage tank. The estimation describes that the rupture time of the reactor pressure vessel was at 8:55 13/3/2011. The estimation shows that the rupture time of the pressure containment vessel (PCV) was at 9:05 13/3/2011. These estimations are different from the ones by TEPCO, however; many measured evidences show good accordance with the present scenario.


全文掲載のPDFファイルダウンロード