浜岡原子力発電所の建屋開口部へのフラップゲートの適用について


英字タイトル:
Use of flap gates at building openings of Hamaoka Nuclear Power Station
著者:
木村 浩樹 Hiroki KIMURA 涌永 隆夫 Takao WAKUNAGA 安田 光博 Mitsuhiro YASUDA 可児 直也 Naoya KANI 木村 雄一郎 Yuichiro KIMURA
発刊日:
公開日:
カテゴリ: 第12回
キーワードタグ:

概要

In order to verify the operational reliability of automatic closure system(hereinafter referred to as “flap gates“) used at air conditioning openings of buildings as a measure to protect Hamaoka Nuclear Power Station against tsunami, operational tests on actual size equipment has been conducted. Tests showed reliable operation in response to repeated rises in the water level. Tests also showed normal operation of flap gates in the case of waves containing debris and sediment.


全文掲載のPDFファイルダウンロード