概要

The accident at TEPCO’s Fukushima Daiichi nuclear power plant on March 23, 2011 was expanded into severe accident (reactor damage and hydrogen explosion). It led to loss of many instrumentation systems, and became difficult to grasp plant state. The instrumentation systems for the severe accident of the nuclear plant are being developed. In order to prevent the hydrogen explosion, the hydrogen concentration sensor is desired to measure the generated hydrogen in the primary containment vessel, and to detect leaked hydrogen into the reactor building. Although almost sensor could not be adopted by the severe accident’s environment, the solid oxide electrolyte type hydrogen sensor was selected for its durability to high temperature and high pressure. In this paper, the developments of the solid oxide electrolyte and the junction of ceramics and metal are described. And the performance test results of the hydrogen sensor under various conditions are presented.