LDIによる局部減肉を考慮した配管系の耐震安全性評価(その3)-配管試験による耐震性への影響の把握-


英字タイトル:
Seismic safety evaluation of piping systems with locally wall thinning by LDI (Part3)-Seismic performance effects of elbow pipes by loading tests
著者:
酒井 理哉 Michiya SAKAI 松浦 真一 Shinichi MATSUURA 森田 良 Ryo MORITA 稲田 文夫 Fumio INADA 尾西 重信 Shigenobu ONISHI 釘本 三男 Mitsuo KUGIMOTO
発刊日:
公開日:
カテゴリ: 第7回
キーワードタグ:

概要

In order to evaluate seismic safety of piping systems with locally wall thinning by LDI, hybrid tests have been conducted incorporating a numerical analysis of whole s ystem with a loading test of elbow model. Seismic performance effects of wall thinning elbow were clarified by comparing three cases of different thickness elbow model s such as no defect, 50% thinning and 75% thinning. By these results, the almost same hystereses of the non-linear load displacement relations were obtained and the dam ages of elbow specimen were not found out by penetrate tests. The static finite element analyses under cyclic loadings were also carried out to consider above results.


全文掲載のPDFファイルダウンロード