原子力発電所2次系配管減肉管理手法の日米比較


英字タイトル:
Japan-U.S. Comparison of Management System of Secondary System Piping Wearing
著者:
千葉 吾郎 Goro CHIBA
発刊日:
公開日:
カテゴリ: 第3回
キーワードタグ:

概要

Secondary system piping was ruptured at Mihama Nuclear Power Station Unit 3 of Kansai Electric Power Company in August 2004, and 11 workers were injured and killed. The operators of PWRs in Japan established and implemented the guidelines for wearing management procedure about secondary system piping. In this study, the management system of Japan and foreign countries were compared, and the validity of the domesti c wearing management technique was examined. Consequently, it was acknowledged a great difference in the maintenance degree of wearing piping by the electric power company in U. S., and the number of repair p ortions of Japan was more than equivalent with upper range of repaired number of U. S.. Therefore, the wearing management system of Japan was compared favorably with U. S. and it thinks that it is appropriate.


全文掲載のPDFファイルダウンロード