常設型薄膜UTセンサを用いた高温時の超音波厚さ測定における校正方法の提案


英字タイトル:
Proposal of calibration method for ultrasonic thickness continuous monitoring at high temperature using a thin film UT sensor
著者:
山本 裕子 板橋 佑真 井原 亮一 川浪 精一 青木 清隆 (三菱重工) 三原 毅 辻 俊宏 (東北大)
発刊日:
公開日:
カテゴリ: 第16回
キーワードタグ:

概要

In this study, in order to propose a calibration method using a correction formula for each steel grade obtained in advance as a calibration method for plate thickness measurement using a permanent UT sensor such as MHI’s Thin-film UT sensor, a temperature-sound velocity correction formula for each steel grade was calculated by obtaining sound velocity values for each temperature from ordinary temperature to 200 degrees centigrade using the Thin-film UT sensor and multiple specimens of steel grade. Using the obtained temperature-sound velocity correction formula, the dispersion of plate thickness values from room temperature to 200 degrees in the test specimen with unknown thickness was less than 0.1 mm (1% t). From these results, it is considered that the temperature-sound velocity correction equation which can be used for the plate thickness evaluation at high temperature was obtained by the sound velocity acquisition test.


全文掲載のPDFファイルダウンロード