Remote Detection and High Precision Evaluation of Wall Thinning Volume in a Metal Pipe


英字タイトル:
Remote Detection and High Precision Evaluation of WallThinning Volume in a Metal Pipe
著者:
Linsheng LIU Yang JU
発刊日:
公開日:
カテゴリ: 第7回
キーワードタグ:

概要

We report a nondestructive method to measure the pipe wall-thinning (PWT) remotely using microwaves. A microwave vector network analyzer (VNA) and a self-designed transmitting and receiving (T&R) coaxial-line sensor are employed in the experi ment to generate microwave signals propagating in the metal pipe where the frequency was swept from 14.08 to 14.12 GHz. A brass pipe with inner diameter of 17.03 mm, 1.0 mm wall thickness, 2.0 m length, and connected respectively with 9 joints having the lengths of 17.0 mm and PWT volumes from 0 to 550 mm were measured. By taking the pipe as a circular waveguide of microwave, after building up a resonance condition and then solving the resonance equations, the remote detection meth od is achieved. By comparing the experimental results with the evaluated ones using our method, it is found that the evaluated results agree well with the experimental ones, it indicates that a high precision evaluation method is established.