可搬型X バンドライナックX 線源によるベアリングマクロ損傷観察試験


英字タイトル:
Macro Damage Observation of Bearing using Portable X-band Linac Based X-ray Source
著者:
山本 智彦 Tomohiko YAMAMOTO 夏井 拓也 Takuya NATSUI 李 基羽 Kiwoo LEE 森 梓 Azusa MORI 平井 俊輔 Shunsuke HIRAI 橋本 英子 Eiko HASHIMOTO 上坂 充 Mitsuru UESAKA
発刊日:
公開日:
カテゴリ: 第6回
キーワードタグ:

概要

We are developing X-ray nondestructive testing (NDT) system using with portable X-band linac. This system uses 2.4 GHz X-band linac and 250 kW magnetron. Our system energy is 950 keV for Japanese regulation. Th erefore we can use it on-site using local radiation protection. We measured electron beam and X-ray. We have started X-ray maging test. We will use this system for condition based maintenance of pump-impeller a t nuclear plants. The linac based X-ray source can generate pulsed X-ray. Therefore we can get still images without stopping rotation when E-ray repetition rate synchronizes impeller's rotation rate. We are suc cessful in proof of principle using a simple fan end a synchronized circuit. We prepare real-time imaging for conventional pump. In this paper, we will explain the letail of this system and experimental results.