ディーゼル機関診断の適用について


英字タイトル:
Application of Diagnostic System for Diesel Engine
著者:
吉永 岳 Takeshi YOSHINAGA 林 治次 Haruji HAYASHI 笛吹 博巳 Hiromi USUI 鶴園 篤哉 Atsuya TSURUZONO 松田 隆文 Takafumi MATSUDA
発刊日:
公開日:
カテゴリ: 第5回
キーワードタグ:

概要

The Japan Atomic Power Company JAPC began to implement Condition Based Maintenance CBM for rotating components pumps, fans and electric motors from 1999and, also has begun to apply diesel engine diagnostic techniques at our three nuclear power plants since 2004 This paper provides a description of the CBM methods used for diesel engines in nuclear standby service, a summary of the procedures to introduce t hese diagnostic techniques to our nuclear power plants, and experience with the application of these methods to JAPC nuclear power plants


全文掲載のPDFファイルダウンロード