誘導型電位差法を用いた SUS304 配管溶接部における応力腐食割れの連続モニタリング


英字タイトル:
Continuous Monitoring of Stress Corrosion Cracking Growth in Type 304 Stainless Steel Pipe Weldments using Potential Drop Method.
著者:
渥美 健夫 Takeo ATSUMI 佐藤 康元 Yasumoto SATO 庄子 哲雄 Tetsuo SHOJI
発刊日:
公開日:
カテゴリ: 第3回
キーワードタグ:

概要

Continuous monitoring of stress corrosion cracking (SCC) in chloride solution containing thiosulfate was performed using type 304 stainless steel pipe specimen with weldments. Induced Current Potentia l Drop (ICPD) method was used to the continuous monitoring of the SCC growth. The ICPD method permit s continuous monitoring of the SCC growth which initiates from the inner wall of the pipe specimen.