配管減肉検査における非接触超音波センサの実機適用に向けた検討


英字タイトル:
Investigation into applicability of a non-contact ultrasonic sensor to pipe-wall thinning inspection of power plants
著者:
田村 明紀 遠藤 正男 河野 尚幸 (日立製作所) 大城戸 忍 (日立GE) Chenghuan Zhong Maria Kogia (Inductosense) Anthony J. Croxford Paul D. Wilcox (ブリストル大)
発刊日:
公開日:
カテゴリ: 第15回
キーワードタグ:

概要

A pipe-wall thinning measurement is required to ensure integrity of a piping system in a power plant. Aiming to reduce the inspection time of the pipe-wall thinning measurement, we have been developing an innovative measurement technology which enables the pipe-wall thinning inspection without removing the insulation, based on the non-contact ultrasonic sensor proposed by University of Bristol. To apply this technology to the actual plant inspection, the sensor durability needs to be confirmed. In this study, we experimentally investigated the temperature durability and radiation tolerance of the sensor. Applicability of the sensor to the small diameter pipe/elbow was also confirmed in the experiments.


全文掲載のPDFファイルダウンロード