高レイノルズ数実流校正設備による給水流量計の校正


英字タイトル:
Calibration of feedwater flowmeter by high Reynolds number calibration facility
著者:
古市 紀之 Noriyuki FURUICHI 寺尾 吉哉 Yoshiya TERAO 高本 正樹 Masaki TAKAMOTO
発刊日:
公開日:
カテゴリ: 第6回
キーワードタグ:

概要

A high Reynolds number calibration facility for feedwater flowmeter in nuclear power plant is described in the paper. This calibration facility is achieved a 1.8×10' Reynolds number which is equivalent one with the actual plant. A calibration res ult of ultrasonic flowmeters, which are used to measure feedwater flowrate in a nuclear power plant, is also described unde r a variety of upstream conditions. Through these calibrations, the calibration method of feedwater flowmeter is suggested.


全文掲載のPDFファイルダウンロード